Dicas Reparação




Modelo - Chassis C8


Pesquisa: C8 Enviar Dica Resolvida
Resultados 212
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
FergusonICC8
Dead 1.6A fuse o/cBUH515 chopper tr s/c; DP50 BY399 HT rect s/c - fit repair kit which includes above parts + CP29 2n2, TEA2261, CP55 220µ & various diodes
FergusonICC8
Dead - no st/by LEDbridge hairline crack at solder pad of DP65 ( 24 volt rectifier feeding line driver )
FergusonICC8
Dead - no 320v reaching chopper trRP01 & 02 1R2 o/c; CP04 4n7 1kv across mains rect s/c
FergusonICC8
Dead - brief burst of HT/EHT with HT at 115v then trips silently - same on dummy loadDL13 BY397 s/c
FergusonICC8
DeadCheck for 10V StBy 6V at TV06 IV01
FergusonICC8
Dark green with streakingRT24, 44, 64 39k 1W fback Rs on crt base all o/c
FergusonICC8
Contrast very lowCheck 39k feed resistors on crt base & 1k flashover prot Rs RT26,46 & 66
FergusonICC8
Blows LOT at switch on HT ok.CL21 11n5 (low capacitance)
FergusonICC8
BLOWS FUSE INTBRIDGE RECT. DIODE PROTECTION CAPACITORS INT SC
FergusonICC8
Blank raster - sound okDL42 1N4148 leaky in pulse conn to pin 35 TA8659CN dec/tb chip
FergusonICC7/ICC8
Cuts out when going to st/by - no Red LEDTV01 BC558C prot Tr
FergusonB59F -ICC8
POOR PICTURE WITH STREAKSCHECK R704 1.5K OHM ON CRT BASE
LGCP20B85 - MC83C
Linhas de retardo na parte superiord401 c/fuga
LG29C85
Foco deficienteTransformador de saída horizontal (Fly back ) avariado
SonyCDXC810DSP
LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163).


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.