Dicas Reparação HITACHI




Modelo - Chassis A5


Pesquisa: A5 HITACHI Enviar Dica Resolvida
Resultados 12
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
HitachiC2976TN A5
Lines at top of pic44v supply to IC601 pin 8 from LOP low at 25v. Check D718/9 BY33J & C725 33nF 400v for o/c
HitachiC2976TN A5
E/W faultyL751 dry joints IC601 TDA8350Q faulty
HitachiC28300TN A5
Long time for pic to appear & white bands acrossC954 1000µ 35v in 12.6v supply
HitachiC28300,C2576TN etc A5 chassis
Red pic with fb linesR829 fusible on crt base o/c (not shown on cct diag)
HitachiC28300,C2576TN etc A5 chassis
Int trips & linesC719 4µ7 250v smoothing cap for 200v in E-W corr & check joints T702 (under plastic strut) & R950 68k near HT pot
HitachiC28300,C2576TN etc A5 chassis
Field lin & lines at top of picC725 33nF 400v
HitachiA5 C2976TN
Sparks around crt base then reverts to st/byLOP stage tuning cap o/c & clean up print on crt base
HitachiA5
To get out of factory pre-set mode (Model & proc type displayed on screen)Hold "Vol+" & "V0l-" buttons in whilst switching on
HitachiA5
To exit Factory Mode (Model displayed on screen)Switch to st/by whilst service mode is displayed
HitachiA5
To enter service modeEnter factory mode by holding "Vol+" & "Vol-" whilst sw on, then press "Tuning" button under flap on r/c
HitachiA5
field faultTDA8350Q & D718 BYD33
HitachiA5
E/W faultyReplace IC601 TDA8350Q


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads