Dicas Reparação GRUNDIG




Modelo - Chassis 80


Pesquisa: 80 GRUNDIG Enviar Dica Resolvida
Resultados 24
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
GrundigCUC2800
The tripler had failed. After replacing it the setMicrocontroller chip type SDA2011 -AOO5 . Make sure that you get the right one for the set.
GrundigCUC2800
Sound low & distU2829B IC sound chip
GrundigCUC2800
Sound from one chan only & no brill adjMicro SDA2011-A005 faulty
GrundigCUC2800
No soundCheck TDA6200 sound proc & U2829B sound dem chip
GrundigCUC2800
Dead - psu working okRelay contacts
GrundigCUC2800
Arcing from LOPTx former to adjacent componentsTripler faulty
GrundigCUC2080
turns on but goes to SB after a secondTDA8350Q + R54012 1Ohm +R50011 33ohm.
GrundigCUC2080
No powerIRFPC50 s/c and 270K (connected to pin 2 of TDA5605-3
Grundig80
Smeary picture - intermittently.Luma delay line leaky.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads