Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | 4CM6099 | VERTICAL FECHANDO INTERMINTENTE. | VERIFICAR POSSIBILIDADE DE FUGA NO DIODO 6402 (1N4148) OU RESISTOR 3410 (100K) ABERTO. * JUNM 95 ANC *. | ||
Philips | 4CM6099 | TELA ESCURA "PRETA" (VEJA TAMBEM BRIL4). | TRILHA ABERTA DO FILAMENTO DO TRC, SUBSTITUIR CAPACITOR 2750 (3N3) E 2772 (10N SMD). * JUL 95 JO *. | ||
Philips | 4CM6099 | SEM SINCRONISMO VERTICAL (VERT5). | VERIFICAR DIODO 6402 (1N4148), COM FUGA; OU RESISTOR 3410 (100K) SMD ABERTO. * JUN 95 ANC *. CAPACITOR SMD QUEBRADO (47nF). * JUL 95 ES *. | ||
Philips | 4CM6099 | SEM PULSO DO OSCILADOR HORIZONTAL. | Resistor 3103 (150K) aberto. * 05Nov96 FR *. | ||
Philips | 4CM6099 | NAO FUNCIONA (FICA COMO DESLIGADO). | VERIFICAR RESISTOR 3103 ABERTO. * DEZ 94 ANC *. Verificar diodo zener 6105 (22V) com fuga. * 02Dez96 JO *. | ||
Philips | 4CM6099 | EXCESSO DE DEFLEXAO | VERIFICAR DIODO 6402 (1N4148) COM FUGA E RESISTOR 3410 SMD DE 100K ABERTO. * JUN 95 ANC *. | ||
Philips | 4CM6099 | DOBRANDO IMAGEM NO VERTICAL | VERIFICAR DIODO 6402 (1N4148) COM FUGA OU RESISTOR 3410 100K ABERTO. * JUN 95 ANC *. | ||
Philips | 4CM6099 | CONTRASTE DEFICIENTE | VERIFICAR SE CHAVE DE NIVEL NAO ESTA EM POSIÇAO IRREGULAR. * DEZ 94 ANC *. |