Philips3LC3000
SEM SINTONIA CANAIS ALTOS. SO CANAL 13 NAO SINTONIZA, REAJUSTAR TUNING CONTROL R675. * NOV 94 ES *.
Philips3LC3000
IMAGEM NEGATIVA. VERIFICAR CABOS DE INTERLIGAÇAO ENTRE PAINEL E DISPLAY LCD, CABO DO +5 DE J202. * JAN 95 ANC *.
SonyKV3000R
COLOR SMEARED LOOKS LIKE BAD CRT, C702 When looking at the RGB outputs on the C Board, the P-Pvideo level was over 300v. This was because horizontal pulses wereriding on the 200 volt +B to the video drivers. Found C702 a 0.47MFD350V open.
SonyEVS3000
WON'T GO TO BLUE SCREEN ON WEAK CHANNELS Blue screen does not come on on all weak channels. When compared with several units, they all worked the same way.
SonyEVS3000
NO FF REW AND EJECT AFTER UNIT WARMS UP-REPL MODE SWITCH After unit warms up it will not playbakc FF, rewind or eject.
SonyITA3000
NO RECORD OAM AND DEFECTIVE OGM REMOTE - RESOLDER IC801 Would not record OGM and no OGM remote. I checked signalat IC801/pin 69, DA out, after recording OGM announcement. No signalcame out. Signal is coming in at IC801/pin 75, MIC1. IC801 chip had alot of pins cold soldered.
SonyITA3000
DEFECTIVE RAM TEST - REPLACE JOG SHUTTLE SWITCH (REF 29) After Ram test, press play and stop button, no function.Switch at shuttle block was defective.
SonyITA3000
NO BATTERY BACKUP - RESOLDER TP50 AND TP51 Battery voltage is not reaching to the main board. I checkedbattery contacts TP51 and TP50. There was not enough solder on them.
SonyITA3000
DEFECTIVE RINGER SELECT - INSTALL R735 In answering mode or OGM activation, select switch at 3 ringsis defective. It takes 5 rings to activate OGM at 3 ringer select mode.I found that R735 is missing on the board.
SonyITA3000
DEFECTIVE PLAYBACK OF OGM AND ICM - RESOLDER IC805 OGM and ICM are cutoff after a few seconds of playback, but intest mode unit will pass RAM test. During visual inspection of board,found IC805 to be poorly soldered. Should RAM test have detected thisproblem?
SonyITA3000
LOW SPEAKERPHONE VOLUME - RESOLDER C504 AND C522 Very low audo when using speakerphone. When tracing audiosignal to IC501, I found both caps C504 and C522 torn off their traces.Resoldering these caps fixed problem.
SonyITA3000
NO SPEAKERPHONE - C512 SHORTED No audio is heard when using speakerphone. Checked voltageson IC501 and they measured 4.2v. Found leads on C512 to be touchingtogether, grounding out RV501 speaker volume.
SonyITA3000
DEFECTIVE BELL DETECT - REPLACE PH201, P/N 8-719-156-79 No OGM activation, constant high at PH201 pin 3 (output).PH201 coupler is defective.
SonyITA3000
NO OGM ACTIVATION - C208 MISSING Defective bell detect test. I traced the signal comingout PH201/pin 3, wave form has a lot of ripple at IC701 pin 14 input. Ifound out C208 missing at the main board.
SonyITA3000
DEFECTIVE ANSWER ON/OFF INDICATOR - REPLACE D702 No illumination at answer on mode indicator. I checked D702and it is cold soldered at diode side.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.