Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | 29PT828C | TRIPS FROM GREEN LED TO RED TO GREEN TO RED | REPLACE IC7450, AND IC7550 ON AUDIO PCB | ||
Philips | 29PT828C | STUCK IN STANDBY | RESOLDER SCAN COIL PLUGS | ||
Philips | 29PT6231 | Interference from adjacent channel | Check, and replace/change posn: 1145 (SAW filter) on chassis to 2422 549 44223 OFWK7260M For /79R, add posn: 1168, 4822 242 81572 6MHz ceramic filter REMARKS : Solution implemented in production | ||
Philips | 29PT6021 | SDM does not work by shorting service pins. | Measure pin 19 of SIMM connector 0226 on LSP, if it is 2V (normal is 1V) then add a resistor of 1K8 between pin 19 of the SIMM connector and ground. Make sure counting left from pin 1, do not use the pin no. printed on service print! See attached ph | ||
Philips | 29PT5324 | Picture distortion (moire) visible. | Picture distortion (moire) visible in the top of the screen. Using one of the EXT-inputs, a picture distortion will become visible in the top of the screen as a horizontal bar (Moire-effect). This distortion is more visible when brightness value is betwe | ||
PHILIPS | 29PT5632/78R NI | Linhas de retraço vermelha e desligando em seguida | CI 7200 trans. horizontal 7461 e 7462 e cap de 47 mf. | ||
PHILIPS | 29PT552A | Funciona por algum tempo e depois desliga. | Transístor TR7461 (BC337). | ||
PHILIPS | 29PT552 | Ao mudar de canal aparece linhas de retraço. | Trocar resistores de 1R, 2R2 e 0,22R estão ligados no emissor do chaveador da fonte. | ||
PHILIPS | 29PT552A LLS | Inoperante. | Capacitor C2463 (1K x 2KV). | ||
PHILIPS | 29PT4631 | NÃO LIGAVA NEM PELO PAINEL NEM PELO CR | VERIFICAR POSIÇAO 2607 CAPACITOR CERÂMICO SMD 33pF x 50V. | ||
PHILIPS | 29PT4631 | Sem Contraste | POSIÇÃO 3481 E 3482 RESIST. 12K E 18K | ||
PHILIPS | 29PT4643 | Cap. 2465 | Vertical dobrado na parte superior com linhas claras no topo | ||
Philips | 29PT5642 /78 - Chassis L04 | VERTICAL FECHANDO INTERMINTENTE. | - Verificar possível alteração (fuga) no capacitor 2461 (CAP CER SMD 1nF). | ||
Philips | 29PT5642 /78 - Chassis L04 | VERTICAL COM POUCA AMPLITUDE | - Verificar capacitores 2245 e 2248. | ||
Philips | 29PT5642 /78 - Chassis L04 | VAI PARA STAND BY APOS ALGUM TEMPO. | - Surge faixa escura na parte inferior após algum tempo de ligado e depois desliga, verificar possível fuga no capacitor 2625, veja detalhe do esquema da seção A5 Features & Conexões.- Verificar Service Information TS04-024 e TS04-027. |