Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Soundwave | CTV1405R | Removing Child Lock | Press Prog up/down buttons on set together for a few secs | ||
Soundwave | CTV1405R | INT LOW BRIGHTNESS 2. STUCK IN CHILD LOCK | C588 DRY BY LOPTX 2. PRESS PROG UP+DOWN FOR 10secs | ||
Soundwave | CTV1405R | Dead - HT ok from psu | Line dr tfmr pri o/c winding | ||
Soundwave | CTV1405R | Dead - hi HT at 250v | Q101 BUT11AX s/c - used BUT11AF; R121 3R3 safety res o/c;due to dry joints D108 | ||
Soundwave | CTV1405R | Dead | Q101 chopper tr s/c & R121 3R3 safety res o/c | ||
Soundwave | CTV1405R | Dead | R599 2k 2w, line dr tr 2SC1573A | ||
Soundwave | CTV1405R | Brightness int goes low | Dry joint C588 near loptx | ||
Proline | 1405R | vertical coloured bands running across screen, no bands on full colour or on zero colour | replace C110 1uF 100V pin 26 of chroma IC | ||
Proline | 1405R | unstable pic, line and frame vibrating/shaking | R407 47k o/c on power supply | ||
Proline | 1405R | UNSTABLE LINE AND FRAME SYNC | CHECK R407 47K IN POWER SUPPLY | ||
Proline | 1405R | stuck in stby | 12V standby supply shorted, replace SMD C434 100nF ( Formenti part no 523145000) | ||
Proline | 1405R | stuck in standby - HT ok, red LED on, no line drive | remove SMD C8 on pin 33 of Micro, clean underneath and refit | ||
Proline | 1405R | red raster with flyback lines | T703 BF421 on CRT base is leaky | ||
Proline | 1405R | RED RASTER WITH FLYBACK LINES | REPLACE T703 ON CRT BASE | ||
Proline | 1405R | int. black bars across screen or int. frame fault | DJ on SMD R304 |