Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Toshiba | 1400RBT/RBW | Field collapse | C303 2µ2 ramp gen cap leaky & C317 2µ2 in lin fb cct leaky causing vert centre fault | ||
Toshiba | 1400RB | Tuning drift | Replace DA34 PtN 23115599 | ||
Toshiba | 1400RB | Field lin dist | C317 (behind field chip) & C303 (behind if can) both 2µ2 & red | ||
Toshiba | 1400RB | Field cramp / stretched at top | C303 2µ2 pin 13 IC501 jungle chip | ||
Toshiba | 1400RB | Auto tune not locking on | Replace QA06 no AFT on pin 8 ICA01 or Replace QA16 no sync on pin 9 ICA01 PtNo 233114689 | ||
Toshiba | 1400RB | 500mA fuse F803 in HT line blew int | 3 rubber wedges on crt conductive - scan coils arcing to them |