Dicas Reparação BEKO




Modelo - Chassis 12220


Pesquisa: 12220 BEKO Enviar Dica Resolvida
Resultados 11
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Beko 12220T
Dead psuC110 defective in psu 47uF, 25V - Resevoir cap for ic
Beko12220T
Dead 55v HTD111 FR30-02 S/C, U4 supply diode
Beko12220NX
The status information appeared on the scrcen at rThe cause of the fault was on the audio panel , where the 17.47MHz crystal Q2 was drifting when warm.§
Beko12220NX
Status info perm/semi perm displayedQ2 17.47 Mhz Xtal on audio pcb drifting
Beko12220 10.2
Front cont int don't workCheck momentary contacts on mains sw
Beko12220
Trips off at sw on - HT = 125v on bulbD801 BY299 s/c - LOPTX could be the cause
Beko12220
Top quarter of screen lit & blank - rest blackR717 1M o/c - connected to pin 5 TEA2029 also check R722 in series 1M
Beko12220
Top ¼ of screen lit, rest blankedR717 1M o/c also check R722 1M
Beko12220
Int pic/sound - disappears with flashing on screen and noise thro speakerXtal Q701 in front of IC701
Beko12220
Col intDec panel plugs int
Beko12220
Blank screen with buzzing & Thy overheatsR725 hi res


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads