GoodmansGTV66W 1 11AK19
Bright white raster at sw on then trips offNo volts to TDA6107Q RGB o/p chip on crt base as 47R safety res R914 on base o/c - dry joint on A1 conn of crt base & others probably caused it
GoodmansGTV66W 1 11AK19
Blank rastersmall RGB panel on CRT pcb had broken print (not surprising as it gets a lot of physical strain)
GoodmansGTV288 11AK19
Dead apart from flashing G LED at sw onR867 0R33 1/2w o/c (not shown on all ccts)
GoodmansGTV288 11AK19-8A
Poor contrast - poor sync - no colour -sound intermittentTDA8843
Goodmans51N1 11AK19
dead power supply pulsating with a clicking noise all o/p vols lowIc901 on crt base
Goodmans11AK19-8
Dead - no st/byR806 22k
FidelityWSTV7028N 11AK19-8A
WidthC630 0.27pF dry joints, Q603 BUK444 leaky, E-W coil shorted turns (looked ok)
Crown11AK19
Dead - LOPTr s/cCheck scan coil conns to main board for dry joints/overheating
Bush, Alba, etc11AK19
blank raster with red green blue flyback lines at the top of picreplace R 704 (marked R702 on cct) 100R in frame output stage.
Bush etc11AK19
Dead - no st/by ledIC 801 opto-isolator.(CQY80NG)
BushWS7671 11AK19P4
Dead - off with a bangIC802 MC44604P, IC801 CQY80NG CNX82 OR SEME TYPE OPT403 OPTOCOUPLER, Q802 2SK2545 MTP6N60E, R822 22K 3W, D807 RL207 BA159, D826 BA159, D827 BA159, D824 MR852 BYW98/200V
BushWS6673 11AK19P5
Dead - D823 blown (not shown on cct)When replaced still faulty, IC802 MC44604P chopper chip u/s - also check FET chopper Tr
BushWS6673 11AK19P5
Dead - check for dry jointsAlso replaced LOPTr which then produced 1" line scan - D622 BY228 leaky & R629 2R7 o/c. There's a mod for psu (11DYC19P) to fit heatsink for diode that burns up
BushWS6671 11AK19P4
Width excessiveQ603 (9NQ20T or BUK444-200 or MTP6N60E)
BushWS6671 11AK19P4
Narrow picDry joint/ o/c C630 560n; R629 27R? Safety o/c, L604 reads 3R (correct), Q603 PHF9NQ20T replaced - used BUK444 200A in lieu


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.