Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
VESTEL | 5566T - 11AK10 11AK10-17 | Falta varredura vertical | Substituir R818 15K 1W | Manuel Cunha | |
Vestel | 5166 - 11AK10-15 | TR da fonte Q801 queimado, volta a queimar logo que se liga o interruptor. | R805 aberta. | ||
CROWN | CTV-5596 # 11AK10-15 VESTEL | Sem deflexão vertical | R-818 AB - alimentação (33V) | ||
Bush | 2068NTX 11AK10-17 | Dead with Q801 P3NA61 Power FET s/c | Replaced with BUZ90 or IRFBC40, TDA4605-2, R809 0R47 1/2w safety res, 330k & R803 820k | ||
Bush | 2028T 11AK10-15 | Dead | Replace R809 (.47ohm) o/c-Q801(BUZ77B) s/c-R805 (330k) o/c - R821 (2.2ohm) surge limit o/c. | ||
Bush | 2028T -11AK10 etc | Standby is initiated when "Vol +" or "Vol -" selected | Corrupted memory IC502 - password reqd when replacing which requires a procedure too long to list here. See Serge's email on subject dated 26/10/00 | ||
Alba | CTV4859 11AK10-17 | Dead | Q801 (BUZ77B), R809 (0.47R), IC801 (TDA4605-3), C817 (1µF 63v), R805 (330k 0.5w), D808 (BA159). |