Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | 10CX1120/05R | power supply working but no line drive. | changed the following T539 / T534 / R537 / R502. LOPT faulty | ||
Philips | 10CX1120/05 | Raster - distorted & no frame sync. | SKE bridge recy. | ||
Philips | 10CX1120/05 | Dist raster & no field sync at sw on - clears aft 10 mins | Mains bridge rect int goes o/c | ||
Philips | 10CX1120/05 | Dead - micro TMS3757ANL-10 | T273 BC557 s/c in AV/RF sw cct also | ||
Philips | 10CX1120/05R | power supply working but no line drive. | changed the following T539 / T534 / R537 / R502. LOPT faulty | ||
Philips | 10CX1120/05 | Raster - distorted & no frame sync. | SKE bridge recy. | ||
Philips | 10CX1120/05 | Dist raster & no field sync at sw on - clears aft 10 mins | Mains bridge rect int goes o/c | ||
Philips | 10CX1120/05 | Dead - micro TMS3757ANL-10 | T273 BC557 s/c in AV/RF sw cct also |