Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
HITACHI | 28LD5200 | No colour Colour drops out after the unit has been running for two to three hours. | Resolder capacitor C510 and other components in its vicinity. | ||
HITACHI | 26LD6200 32LD6200 | Unit does not work, standby LED not lighting | Replace Ferrite bead L500 and L501 with a jumper wire. | ||
HITACHI | 26LD6200 32LD6200 | No pictures or lost after 10,20sek | replaced inverter board(P.Suplly)17PW11 | 2 (24Volts) | |
HITACHI | 26LD6200 | Lines on the screen,strange picture | Replaced cable from main board to the screen. | ||
HITACHI | 22LD4200 | Stby redlight go green and back to red | Transistor(Q104 BC548) and Resistor (100oM). | ||
HITACHI | 22LD4200 | Flashing green line | Green horizontal line flashing across the screen intermittently | Remove resistor R149 on the Input signal board and replace it with Jumper SMD (0 W) | |
HITACHI | 22LD4200 | Lines on the picture | Bad conection between PS(PL108) and VIdeo board (PL100) . | ||
HITACHI | 22LD4200 | No pictures sound ok | after diferent time CHECK 5v on 17amp07 p/s board if less 3,0 or 1,5 replaced C111(25v1000mkgf) | ||
HITACHI | 22LD4200 | Lost picture after diferent time | Dry joints on video procesor IC100 board (17MB10). | ||
HITACHI | 15LD2200 | No pictures | Fuse F1 and C16 or C5(150n) on inverter board. | ||
HITACHI | 28LD5200E | COR INTERMITENTE OU SEM COR. COR DESAPARECE DEPOIS DO APARELHO TRABALHAR 2 OU 3 HORAS. | C510 CAPACITOR. RESOLDAR OUTROS COMPONENTES EM SUA VIZINHANÇA. | C Santos | |
HITACHI | 22LD2200 17MB18 | Sem backlight | Ver condensadores C5 e C16 no Inverter | Paulo Andrade SulRep | |
PHILCO HITACHI | PCR2041 | COM A TELA COMO SE ESTIVESSE FORA DE FOCO | SOQUETE TRC TROCA DO MESMO | RUSSOTV.COM. | |
PHILCO HITACHI | PC2004 CPH02 | Não da a partida. engostando a ponta de prova positiva do multiteste no corpo do fly back e o negativo no terra, no momento em que liga o ponteiro aciona e logo desliga. (presença de alta tensão). | Este sintoma pode ser causado por C914,911,909,908,912,722,R703,907,909,908 ou fly back. | Ademir tc | |
PHILCO HITACHI | PC2041 | fechando um pouco vertical em cima e em baixo tremendo | depois de trocar quase todos os eletrolicos e não resolvia passei o capacheque no c908 | trocar c 908 10 micro por 50v | marciorvgo |