Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Toshiba | 2512DB | STATIC DISCHARGE FROM SPEAKER GRILLS | USE STATKIT TO DIRECTLY CONNECT GRILLS TO CHASSIS ( SUPERCEDES JULY BULLETIN RE FITTING NEW CABINET ) | ||
Toshiba | 2512DB | Shrunken and non-linear frame | C372 (2u2F 50v), C374 (220uF 16v), C372 (2u2F 50v) which are all mounted under a screening can on a sub panel at the front right (as seen from the rear). Also C317 (2u2F 50v) positioned under the overhang of the sub panel on the main board. | ||
Toshiba | 2512DB | PSU trips one minute after switch one, could be int or random | ground pin 52 of IC501, ref Toshiba technical | ||
Toshiba | 2512DB | Non lin field | Caps (2µ2 & 220µ) in screening can on small pcb back RHS of main pcb | ||
Toshiba | 2512DB | No st/by, small raster after LOPTx replacement | Q845 st/by sw tr 2SC2023 - BUT12A used in lieu | ||
Toshiba | 2512DB | LOW WIDTH + EW FAULT R425 OC | L423 SHORT TURNS | ||
Toshiba | 2512DB | Lack of width. | R425 o/c , loading coil L423 ( TX100 EW PCB ) width , EW adj via H/set | ||
Toshiba | 2512DB | lack of width & cogging from cold | C424 4µ7 100v on sub panel at front rh of chassis | ||
Toshiba | 2512DB | Int crackling/static noises fro rh chan in st/by | Resold joints in audio o/p chip area | ||
Toshiba | 2512DB | in stby after LOPTx and LOPTr 2SC2023 replaced | Q843 2SA1321, Q842 2SC2230 | ||
Toshiba | 2512DB | FIELD JITTER , PIC BREATHING | Q833 ( S1854 - Toshiba A6907751 ) | ||
Toshiba | 2512DB | EW faulty | Check all elects on stand up EW panel | ||
Toshiba | 2512DB | Dead | Replaced TDA4601 and SE140N | ||
Toshiba | 2512 -252 | BLACK FLASHING LINES RUNNING UP THE SCREEN WORSE W | ICV01 TA8777N AV SWITCHING IC | ||
Toshiba | 2507DB | Focus slightly out & int brightness | CRT faulty |