Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | 4CM8290 | LARGURA EM EXCESSO | Resistor SMD 3608 (1K2) com solda fria. * Nov 95 ANC *. Fuga no diodo 6624 MUR460. * Nov 95 ANC *. Transistor 7618, 7621 (BUK453) e 100Û. * 02Dez96 JO *. | ||
Philips | 4CM8290 | FORA DE QUADRO, DESCENTRALIZADO. | VERIFICAR CAPACITOR 2303 (100nF). * MAI 95 ACM *. | ||
Philips | 4CM8290 | DESLIGA LOGO APOS LIGAR. | VERIFICAR LED 7 DESTE MODELO. * DEZ 94 ES *. CAPACITOR 2935 ABERTO (2,2µF). * AGO 95 ANC *. | ||
Philips | 4CM8290 | DESLIGA INTER. OU PROTEGE (REW 3 P/ VCR). | Solda fria no resistor SMD 3608 (1K2). * NOV 95 ANC *. | ||
Philips | 4CM8290 | DANIFICA RESISTOR | RESISTORES 3646/3650/3657, VERIFICAR FET 7624 (BSN254A). * MAI 95 ANC *. | ||
Philips | 4CM8290 | DANIFICA BOBINA OU TRAFO. | BOBINA 5613, VER TRAFO 5612 COM FUGA. * MAI 95 ANC *. | ||
Philips | 4CM8290 | CHEIRO DE QUEIMADO OU COM FUMAÇA. | VERIFICAR FET 7624 (BSN254A), RESISTORES 3636/3650/3657 DANIFICADOS. * MAI 95 ANC *. | ||
Philips | 4CM8290 | BRILHO NAO ATUA | Resistor 3533 (75K) aberto. * 26Fev96 JO *. | ||
Philips | 4CM8290 | AQUECE BOBINA | AQUECE BOBINA 5613, VER TRAFO COM FUGA 5612. * MAI 95 ANC * | ||
Philips | 4CM8290 | AO LIGAR APARECE RUIDO FORTE | CAPACITOR 2152 ALTERADO (68µF). * AGO 95 ANC *. | ||
Philips | 4CM8270 | NAO FUNCIONA (FICA COMO DESLIGADO). | Transistor de saida Horizontal 7617. * 20Dez95 JO *. Diodo 6614 em curto ver 7608. * 1ºAbr97 JPBA *. | ||
Philips | 4CM6282/78 | VERTICAL TREMULO (ONDULANDO) | Capacitor SMD com fuga 2431 (100nF). * 27Jan96 ANC *. | ||
Philips | 4CM6282/78 | VERTICAL CORRENDO (SINC2). | CAPACITOR SMD 2305 (4N7) QUEBRADO, cuidado no esquema o valor esta errado (1n5). * MAI 95 ANC *. | ||
Philips | 4CM6282/78 | VERTICAL COM POUCA AMPLITUDE | FUGA NO DIODO 7323 (BZX79C27). * MAI 95 ANC *. | ||
Philips | 4CM6282/78 | TELA ESCURA EM 640 X 480. | CAPACITOR 2305 SMD (4N7) QUEBRADO. * MAI 95 ANC *. |