Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Hitachi | C24W410 | Int crackle on sound | R4005 & 4009 47R in audio o/p cct | ||
Hitachi | C24W1TN | Slow to or won't come out of st/by | Caused by the micro prog initilisation not getting past auto greyscale sequence due to A1 setting too high - adj A1 as per service instructs | ||
Hitachi | C24W1TN | Int reverts to st/by | Dry joints IC951, Q601 & Q602 reg | ||
Hitachi | C24W1TN | Int off - esp when tapped | Dry joints VR950 in PSU | ||
Hitachi | C2416TN | Sound missing | Memory IC002 | ||
Hitachi | C2236 | WHITE SHADOW LHS SCREEN | CHECK C715 ( 2.2uF 350V ) | ||
Hitachi | C21P228 | Int trip | C715 dry joints | ||
Hitachi | C2166TN | Trips off soon after sw on | Dry joints R719 in trip network, also checks for drys on regs | ||
Hitachi | C2166TN | St/by only aft poor start up | Dry joints IC952 (under plastic rail) | ||
Hitachi | C2166TN | St/by only aft initial EHT rush | Dry joints IC951/2 | ||
Hitachi | C2166TN | Sound absent | IC002 Hitachi Part No. E730045 | ||
Hitachi | C2166TN | Int trips | Remove glue from IC950 & surroundings | ||
Hitachi | C2166TN | Int trip | IC952 5v reg faulty | ||
Hitachi | C2166TN | Dead with dim st/by light | Dry joints IC902 | ||
Hitachi | C2164TN C2564TN | WONT START , JUST MOMENTARILY ENERGISES THEN DIES | CHECK 25v SUPPLY TO AUDIO |