Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Beko | AT3 | Dead - tripping | R111 820k 1/2w, R112 330k 1/2w o/c | ||
Beko | 6BZ190-11 | Dead - psu burn up | IC901 MC44603, T901 FET P3NA60 use 2SK2545, R911 1k | ||
Beko | 35228T | Low sound with osc | Add 68k resistor & 68pF cap across C344 18pF on Nicam panel (unofficial) | ||
Beko | 30328T | St/by only | No line - line dr tr T801 o/c | ||
Beko | 30128T | Lop tr goes s/c | C140 22n 400v o/c | ||
Beko | 30128T | Dead & ticking | BU508DF LOPTr s/c, C140 22n 630v o/c | ||
Beko | 30128T | Dead - LOPTr blown & twitching/flashing when replaced | R149 Surface mounted resistor should be 1K5, was up to 41K | ||
Beko | 2841ND - 14.1 chassis | Lines across top 3 - 4 inches of pic | R422 35v feed to IC501 fop chip never been soldered | ||
Beko | 2832T | Pic takes a long time to appear | R213/4/5 22k on crt base or LOPTx | ||
Beko | 28328NX | Nicam drop out | Reset variable cap C678 for 2.8v at pin 1 IC603 | ||
Beko | 2812NX | Field scan partially missing & no tuning | R200 o/c (4R7) and IC200 TDA8170 S/c | ||
Beko | 28128NX 11.1 | Dead aft smoke | LOPTx u/s 058.541-TR1 R118 10k 0.5W in beam current sensing burnt R110 4.7R 0.5W fusible o/c in +200V supply | ||
Beko | 28128NX | Dead & tripping psu | S/C BU508DF LOPTr - when replaced int width variations - caused by wire on Line Dr Trfmr not soldered | ||
Beko | 28128 11.1 | No video via scart | TDA8361 | ||
Beko | 25411ND | Bright raster with sound | Pic can be restored by altering A1 or Focus control - CRT faulty |