AiwaVXT1000 Mk2
DeadHt ok at 120v - ICP1 o/c
AiwaVXT1000
STK7348 chopper chip int failsC88 3300pF 1kv can be the cause even tho' it looks ok
AiwaVXT1000
Dead TV sectIC4 STK7348, R103 1R5 3w, R104 27R 3W, R105 1k 1/2w. C90 1µ 50v was to blame
AiwaVXS140
TV sect remains on (No st/by)115V power switching transistor Q550 [2SB816E] was S/C C-E
AiwaVXS140
Lack of brightness on Video playback & off airNo 800V screen drive Increase FR752 from ( 1K ) to ( 1K5 ) PtNo 87022388060
AiwaVXS140
Blank raster & no VCR funct except clockFR551 [0.1 ohm 1/6 Watt] O/C
AiwaVXG142K
No sigsQ1029 (2SC926) at rear of vcr pcb s/c - used a BD234
AiwaVXG142K
No pic or vcr mechs - osd & sound okReplacing the faulty switching transistor Q511 [2SB926] which supplies the chroma +9V cured both faults. It is situated at the back LHS of the VCR board.
AiwaVXG142K
Dead with fast tripping aft power cutC513/C538 1m 160v in psu hi esr
AiwaVXG142K
Dead with st/by led lit - accepts a tape but no functsICP506 1A CP on tv pcb o/c
AiwaVXG142K
Dead - no stbyR516 270k, IC501 TDA4605-3, Q500 2SK2397
AiwaVXG142K
Dead - no st/byR516 270K, IC501 TDA4605-3, Q500 2SK2397-01MR
AiwaVXG142
No raster - OSD OKQ1029 near tuner
AiwaVXD2120K
Pin code resetting when lostunplug set for 1 hour plus. reduce volume to minimum. simultaneuously press Volume down on unit and "7" to reset pin code and customer ID
AiwaVXD1420
Pin code removalEnter wrong no 3 x, then press Vol- on set & "7" on R/C for 5 secs when "protected" appears


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.