Dicas Reparação GRUNDIG




Modelo - Chassis


Pesquisa: GRUNDIG Enviar Dica Resolvida
Resultados 797
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
GrundigCUC120
No picture - EHT & sound ok.D2764 ( SKE2F1 ) o/c.
GrundigCUC120
No luminace.D2536 ( IN4148 ) leaky.
GrundigCUC120
No cold startC626 reservoir cap o/c
GrundigCUC120
Lack of frame at bottom when cold.C2768 ( 100uf ) on deflection PCB.
GrundigCUC120
Intermittent shut down.IC TDA4600 plus check drys on L631 off base of chopper Tx.
GrundigCUC120
Intermittent shut down.Dry joints on L631 off base of chopper Tx.
GrundigCUC120
Intermittent going into standby.Change R647 to ceramic.
GrundigCUC120
Interference at sides.IC TDA2595 sync/line osc IC.
GrundigCUC120
Int luminanceC2527 0µ1 faulty
GrundigCUC120
Frame distortion.IC TDA1770 if used , D2761 ( SKE4G1/04 ) , R2761 ( 6.8ohm , .75W )
GrundigCUC120
Frame collapse - sound ok.D2764 ( SKE2F1 ) o/c.
GrundigCUC120
FIELD FAULTSC2768 D2761 R2761 6R8 PRESETS OR TDA1770
GrundigCUC120
Dead.C633 ( 100u f ) s/c.
GrundigCUC120
Dead - BU208 s/c.Check for C633 ( 100uf ) s/c , R646 , replace C631.
GrundigCUC120
Blank raster & muted sound.Drys in IF unit try on pin 12 were 12v supply comes in.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads