Dicas Reparação GRUNDIG




Modelo - Chassis


Pesquisa: GRUNDIG Enviar Dica Resolvida
Resultados 797
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
GrundigCUC220
Frame collapse.R2779 ( 18k ) o/c remove to check.
GrundigCUC220
Excess col & brightness when heatedOK when Txt pcb dis'd - left it this way
GrundigCUC220
Display - intermittent incorrect channel dispIC663 ( 5v reg )
GrundigCUC220
Dead - intermittent.R646 ( 270k ) on PSU.
GrundigCUC2131
No powerR60502 (3M Ohm 2watt) open circuit
GrundigCUC2080
turns on but goes to SB after a secondTDA8350Q + R54012 1Ohm +R50011 33ohm.
GrundigCUC2080
No powerIRFPC50 s/c and 270K (connected to pin 2 of TDA5605-3
GrundigCUC2059
Dead - chopper tr T60006 blown
GrundigCUC2058
St/by onlyTripler - cheaper from CPC
GrundigCUC2058
No sound/pic - could be into/c print under small vert panel with 10 pins behind tuner
GrundigCUC2058
No sound Both audio o/p IC`s TDA7265 & 2.5A wickman fuse o/c
GrundigCUC2058
Dead with blackened fusep. supply FET IRFPC50 was s/c due to 270k res in psu o/c, also replaced TDA4605-3 as a precaution
GrundigCUC2058
DeadTDA4605, 270k 1/2w res & chopper FET IRFPC50 (used 2SK2078 in lieu) - all in PSU
GrundigCUC2040
TrippingLOPTx (29221-029.52A) s/c, Seme HR6574 15.42 UKP.
GrundigCUC2032
DeadBUZ90 SMPS T60006 s/c & fuse SI60001 1.6S o/c - caused by R60001 270k & R60007 120k hi res also TDA4605-3


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads