GrundigCUC2200
Small pulsating raster.Di614 ( 75v zenor ) in cutout circuit rev leak around 100k
GrundigCUC220
Startup - switch on problems & hum.Relay contacts jammed o/c.
GrundigCUC220
Standby- intermittent going into standby.IC663 ( 5v reg )
GrundigCUC220
Standby - intermittent going into standby.Change R647 to ceramic.
GrundigCUC220
Shutdown - intermittent switching off.Dry R646 ( 270k ) , TDA4600 , replace HT pot R647 ( 2.5k )
GrundigCUC220
Pulling/RollingC2216/2221 1µ 63v in IF can by TDA5500 chip
GrundigCUC220
No vision with raster and sound.T2533 , Adj control SB , R2536 , C2536 , D2536 , D2532
GrundigCUC220
No pic at switch on - looks like its off tuneC2221 ( 1uf 63v ) in tuner/if unit.
GrundigCUC220
Lack of frame at bottom when cold.C2768 ( 100uf ) on deflection PCB.
GrundigCUC220
Interference at sides.IC TDA2595 sync/line osc IC.
GrundigCUC220
int start upTDA4600
GrundigCUC220
INT START UPC631 100uF 40v , C633 220uF , C647 1uF , C642 100uF + R646 270k
GrundigCUC220
Horizontal shaking.Tuner/IF dry joints , check the electrolytics with freezer
GrundigCUC220
Goes straight off at sw onodd characters in display - HT = 180v (109v) HT pot int
GrundigCUC220
Frame distortion.IC TDA1770 if used , D2761 ( SKE4G1/04 ) , R2761 ( 6.8ohm , .75W )


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.