SintomaCausaSoluçãoPor:
SonyCDP101
FUSIBLE RESISTORS R390 AND R391 Door opens slow. R390 and R391 was charred and IC304 wasreplaced as precaution.
SonyCDP101
DEFECTIVE CRYSTAL 1) Disc motor would run at power on. 2) No loading orchucking operation. 3) Sometimes pause and play, LEDs would light.4) Sometimes drawer would open partly.
SonyXR85
LOADING DRIVE BELT STRETCHES Loading drive belt stretches and belt will slip. When thebelt slips the cassette will not load.
SonyXR85
INCORRECT PART NUMBER IN MANUAL A tech. ordered a volume control (R/N 502 in the S/M) by theparts number 1-228-735-00 but he received the part 503, instead.
SonyWM10
COLD SOLDER JOINT ON FLEXIBLE BOARD Unit stopped rewinding or fast forwarding several secondafter pressing REW or FF button. Found cold solder on the flexible boardbetween S901 and R634 as indicated in the diagram.
SonyTCK88B
UNIT OUT OF ADJUSTMENT Dealer complained of gross wow and flutter. Verified problem,measured 0.6% JIS weighted.
SonyTCK88B
LOOSE WIRE BETWEEN SERVO BOARD AND SYSCON BOARD Counter was intermittently not advancing. Determined thatIC602 derives count from supply reel revolutions using output of Q536 andQ535 on servo board.
SonyTCFX77
MISSING PART # IN MANUAL There is no P/N for the capacitor C134, 234 (56pF/500V),which are connected to the R/P head, in the service manual.
SonyTCFX44
DEFECTIVE RELAY Erratic system control operation. When record button isdepressed, unit will intermittently enter rewind mode after 2-3 sec(record deactivates). Results from high resistance of relay contacts.
SonySPP11
SERVICE MANUL INSTRUCTIONS P31. Lacking a linear detector, I adjust RV2 to energizebase relay.
SonySPP11
SERVICE MANUAL INSTRUCTIONS P10 of service manual instructs tech. to turn RV6 CCW forfreq. adjustment. It is my belief that it should read RV5, instead.
SonyPSX800
GLUE ON S/N 800439 Intermittent cue up/down malfunction. Symptom was no dampingaction. Checking output of vert. MFB DET coil with scope showed inter-mittent no signal or noisy erratic signal. Tan glue on the solderpads of the coil's PCB in the bearing assy caused proble
SonyPSX800
OPEN LEAD IN S/N 802218 Intermittent cue up/down malfunction. Symptom was no dampingaction. Checking output of vert. MFB DET coil with scope showed inter-mittent no signal. An open lead, confirmed with ohmmeter was the cause.
SonyKV1222R
BRIGHT PICTURE WITH RETRACE LINES Set would come on OK when very cold. Then after abouta minute, pix would get very bright and have retrace lines.
SonySTRAV880
NO POWER - UNIT DEAD Unit had no power - completely dead.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.