Dicas Reparação




Modelo - Chassis


Pesquisa: Enviar Dica Resolvida
Resultados 81386
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKV2675R
SNOWY PICTURE, Q-201 UHF AMP ON "A" BOARD Picture was snowy on both VHF/UHF.
SonyKV2675R
CRT ARCING AND VERTICAL ROLL, CRT SOCKET Set would arc (more like a loud tick noise) then picture wouldvertical roll for about 20 to 30 seconds, until the next ticking noise.
SonyKV2650R
SNOWY PICTURE, REPLACED BAND SWITCH IC002 The set would occasionally tune in the VHF low channels. Allother channels were snow. We found the band switch IC to be defective.This is becoming more common problem with the units using the LA7920 IC.
SonyKV2649RX
MISLANDING, REMOVED SHORT When viewing pix at low brightness, the edges of the rasterappeared reddish in color. Inspection revealed slight distortion in redinput signal to video drivers. I found the output terminal on the AVboard had a lead shorting to the junction of R12 and R
SonyKV2649R
NO VERTICAL DEFLECTION, REPLACE C508 The set had two problems. No vertical deflection. Thewaveform at Pin 7, IC502 was pulsing, all the voltages were fine. FoundC508 had a 47uF instead of a 1uF that the manual calls for. The secondproblem was no high band. Found the UHF and VHF output
SonyKV2145R
NO V DEFLECTION, REPLACE Q502/503 & R520/R555 Vertical problem.
SonyKV1961
SPUTTERING OF THE AUDIO, REPLACED LAMP On channel 7 only, you would hear a sputtering of the audio.
SonyKV1952RX
DEAD, REPLACE HDT T501 Unit came in dead, found horizontal output (2SD1938) shortedand fuse open. After replacing output transistor and fuse, foundincorrect waveform on horizontal drive transistor. Found HDT (T501) tobe defective.
SonyKV1946R
INTERMITTENT SHUT DOWN, LEAKY D502 Unit would shut down intermittently.
SonyKV1924
SPOT BURNING ON CRT Set came in for a burnt spot center of screen (size about1/8 inch). Servicer replaced picture tube and after two months set camein again, same problem with new tube.
SonyFD20A
NO PICTURE, REPLACED LEAKY C603 No picture.
SonyKX2501
INTERMITTENT SHUT DOWN, REPLACE HVR BLOCK Unit would shut down intermittently.
SonyKV9200
RETRACE LINES ON DARK SCREEN This unit had retrace lines with brightness control turneddown.
SonyKV5300
TUNER ASSEMBLY TOUCHING FUSE HOLDER Tuner assy touching fuse holder F601. Repaired six units withsame problem.
SonyKV2675R
NO VIP, RESET PROCEDURE Set snaps then VIP will not work, screen scrambled (1 end-user, 2 dealers). Also, IC104 (CX7958) will kill remote (another set).Snapping seems to come from pix tube. -HQ COMMENTS: As a first approach to the problem, please perform thefollowing reset pr


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.