Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDV8 | PLAYBACK JITTER AND NOISE | Cleaned, no help. | ||
Sony | CCDV8 | PINS BENT ON 24 PIN CONNECTOR | Pins 23 and 24 were bent. -HQ COMMENTS: Pins 23 and 24 are not used on the multipin connector.The recommended solution if pins 23 and 24 are bent is to cut them off atthe base. | ||
Sony | CCDV8 | INTERMITTENT NO FUNCTION | Osc change frequency. | ||
Sony | CCDV8 | NO EJECT | Frozen motor. | ||
Sony | XR66 | NO MANUAL AUTOREVERSE | Unit will auto reverse at the end of the tape but not whenthe front panel buttons are pushed. | ||
Sony | CCDV8 | PLAYBACK PICTURE UNSTABLE AFTER 1 - 2 HOURS | After approx. 1 to 2 hours of operation drum and capstanservos would become erratic. Picture would jump from side to side andtracking noise would appear. Also, capstan would not run at all. Inter-mittent capstan (from play or REC mode) would cause shu | ||
Sony | SL2500 | REWIND PROBLEM | Close inspection of enclosed upper drum revealed a slightimperfection (marked). Replaced again OK.-HQ COMMENTS: We will evaluate this sample and inform you of our results. | ||
Sony | D5 | STATIC AFTER 10 TO 30 MINS | Unit has static after warm-up. | ||
Sony | CCDV8 | NO EJECT | Unit came in with tape jammed inside. I found that the unitwould not unthread, it would play fastforward and rewind. | ||
Sony | CCDV8 | SHUT DOWN AFTER 5 SECONDS | This particular unit was going into shutdown. After 5 secondsof play, the unit performed all function for that 5 seconds. The onlytime the unit worked without shutting down was on still. | ||
Sony | BMC550 | NOISE IN AUDIO ON QUIET SCENES | Customer complains about background noise from auto focus andmechanism. CS-5 board changed. -HQ COMMENTS: Due to the proximity of the microphone to the focus andzoom motors, acertain amount of noise is unavoidable during quiet scenes.Reducing the gain | ||
Sony | CDP102 | WRONG MOTOR COIL WIRING | Motor coil wiring is wrong for L152-2 on hook up/board layoutpages. This coil is shown connected out of phase. Copy of Page 40/41 ofCDP-102 manual attached. Note corrected copy. -HQ COMMENTS: Confirmed the wiring of L152-2 should be crossed as youfou | ||
Sony | SL2700 | CROSS TALK | This unit had bad cross talk on both channels. The outputsfrom the band pass filters was not clean. BPF-801/802/901/902 wereall bad. | ||
Sony | CDP200 | DRAWER WILL NOT OPEN | The drawer would not open because the chucking motor (M802)gear penetration was too tight. | ||
Sony | XO5 | LOW TORQUE | This unit had low take-up torque and would not rewind or FFto the end of the tape. |