SintomaCausaSoluçãoPor:
SonySTRAV1010
MISSING ADJUSTMENT PROCEDURES FOR AMP BIAS CURRENT The service manual has no adjustment procedures. I referredto Supp.#1 for STR-AV1000 and it says 0.01mV within 30 seconds after poweris turned on, equalling 100uA bias current. The STR-AV920/1020 S/M says4mV within 30 seconds after the power is turned
SonySTRAV910
MISSING ADJUSTMENT PROCEDURES FOR AMP BIAS CURRENT The service manual has no adjustment procedures. I referredto Supp. #1 for STRAV900 and it says 0.01mV within 30 seconds after poweris turned on, equalling 100uA bias current. The STR-AV920/AV1020 S/M says4mV within 30 seconds after the power is turned
SonyICFC200W
DEAD SET - C104 AND PT101 Dead set. Power transformer primary open. C-104 shorted andset has no fuse.
SonySPP50
PAUSE FUNCTION WORKS ONLY IN PULSE MODE The pause function works only in pulse mode and not in thetone mode.
SonyKV27HFR
SHUTDOWN, REPLACE R-505 Shutdown due to excessive Hi voltage disconnected H-out andchecked horizontal waveform at pin 11 of IC-301. Frequency was 7 kHz.adjustment of FH control (RV-501) would bring into specs. Checkedresistance of RV-501 and R-505. R-505 read 1.5 Meg (should
SonySLHF1000
POOR PICTURE BETA I Poor Record/Playback of Beta I - marginal tracking. Picturequality is grainy. RF envelope lower than normal - most noticeable inBeta I. Found voltage at IC-004 (PV-2) board to be 4.9V at pins 1 and 2.Discovered R-16 to be 10 Ohms instead of 1 Ohm. Pr
SonyKV19TR20
P/N FOR ANTENNA IN S/M IS INCORRECT, 1-501-372-41 Service manual says 1-501-372-21 is the antenna for thismodel. However, it doesn't fit the unit. -HQ COMMENTS: 1-501-372-41 is the correct antenna for this model.Please correct your service manual.
SonyKV19TR10
P/N FOR ANTENNA IS INCORRECT IN S/M, 1-501-372-41. Service manual says 1-501-372-21 is the antenna for thismodel. However, it doesn't fit the unit. -HQ COMMENTS: 1-501-372-41 is the correct antenna for this model.Please correct part number in your service manual.
SonySTRAV380
INPUT FUNCTIONS WON'T CHANGE - BUT DISPLAY INDICATES CHANGE Set locks onto one input function and regardless of selectedfunction, all audio output is from the function locked onto. The displayindicates whichever function key is depressed. The set would sometimesfunction normally until warm.
SonySLHFR70
DRUM ASSEMBLY REPLACEMENT DOES NOT FIT PROPERLY Original drum has cut-out. The replacement does not.
SonyKV27HSR10
UNIT DISPLAYED UNSYNCHRONIZED PICTURE AT TURN ON, D-505 Unit displayed unsynchronized picture at turn on but after afew seconds, picture would lock up.
SonyXR5500
MISSING PART NUMBER FOR PM900 The part number for the plunger solenoid shown on page 13 asPM-900 does not have a part number listed. The same solenoid is shown onpage 15 as PM1.To Tokyo: What is the part number of this solenoid which is shown as twodifferent references?Tokyo Fax:(RE
SonyD2
SLED MOTOR BINDS Sled motor binds, sometimes it comes back after a short timeof use.
SonyKV19TR20
REDDISH VERTICAL LINE, ADJ H REQ. RV-501 There was a reddish vertical line about 1 1/2 inch wide inabout 1 inch from the left side. Very noticeable when no color ispresent. This was caused by the horizontal AFC being slightly offcausing a phase shift problem.
SonyCCDF45
REPLACEMENT LENS REQUIRES NEW SCREWS The new lens has to be mounted with part number 3-335-640-11(2 each) screws. A service bulletin should be issued concerning themodels using this lens. -HQ COMMENTS: The CCD-F35/F36 and the CCD-F45/F46 use the new screws The part number of the CCDF35/36


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.