SintomaCausaSoluçãoPor:
SonySLV353UC
WON'T TURN OFF DISPLAY (NO FUNCTIONS OPERATE) When unit is plugged in (power on), immediately comes on andwon't turn off, no functions operate, won't load a tape. Looks like microis locked up. Note: When the cam motor was taken out of the unit and a DCvolt applied to it, it intermittently ran for
SonyCDPC205
DAMAGED LOADING GEAR Unit will either not open and close properly or the drawerwill close, open slightly and then reclose.
SonyCDPC305
LOADING GEAR Unit will either not open and close properly or the drawerwill close, open slightly and then reclose.
SonyCDPC9ESD
DISC DOES NOT GO INTO UNIT Some discs are jamming when they go into the magazine. -HQ COMMENTS: A similar problem was found in a CDPC100. As mentioned inFPR No. L1070, some wear and scratches on the metal spring inside themagazine were found. By filing the contact area on the s
SonyKX2501A
FOLDOVER AT TOP (VERTICAL), REPLACED C518 There is a foldover at top of screen (vertical).
SonyKV1554R
THIRD CHANNEL POSITION STUCK IN HIGH BAND The third channel position (normally channel 4) was stuck inthe HIGH band. All other channel positions worked properly. The problemwas caused by D-005 on the M-1 board. The diode checked good with a DVMin the diode test position. A common failure wit
SonyDTC75ES
INCORRECTLY WIRED DAT ERROR INDICATOR JIG CONNECTOR CABLE The connector cable used to interface the error indicator jig(P/N J-8000-001-A) to the unit is wired backwards. This causes all threeleds to steadily light when the A head is monitored and no leds will lightwhen monitoring the B head. This has been ver
SonyDTC700
INCORRECTLY WIRED DAT ERROR INDICATOR JIG CONNECTOR CABLE The connector cable used to interface the error indicator jig(P/N J-8000-001-A) to the unit wired backwards. This causes allthree leds to steadily light when the A head is monitored and no ledswill light when monitoring the B head. This has been verifi
SonyTCW390
MUTES LINE OUT WHEN RECORDING FROM LINE IN When recording from line in, the line out is muted. However,if you are recording from deck to deck, line out is not muted. I believethis is normal. The TCW-390 is part of system package and does not usethe line out when recording from line in. Is thi
SonyCCDF50
NO PICTURE ON PLAYBACK After five minutes of warm up, the picture on Playback will godark. Sound was fine.
SonyCCDTR6
NO COLOR RECORD Unit won't record color, playback of pre-recorded tapes is ok.Tried resoldering CN-202 on VS-63 board with no results.
SonySLV676UC
BLUE SCREEN CORRECTION HIC BOARD
SonyICF7601
NO AUDIO UPON POWER-UP Unit powers up - no audio.
SonyD25
DISC DOES NOT SPIN Disc does not spin. Open line between IC-502 pin 39 - spindleoutput and IC-504 pin 37.
SonyD66
DEAD UNIT Dead unit 3.5 volts B+ for micro IC-801 missing. C-424shorted.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.