SintomaCausaSoluçãoPor:
SonyCFSW320
REPLACEMENT MOTOR M-101 DOES NOT WORK The replacement motor M-101 part number 3-393-882-01 does notwork. Many motors were tried from stock and none of them worked. Thereplacement motors never got up to speed. The replacement motor is a 12 Vmotor. The original motor is a 9 V motor. The u
SonyTCDD3
REPLACEMENT GEARS FOR MECHANISM The mechanism gears are still not available for the TCD-D3. -HQ COMMENTS: According to Tokyo's fax A911168 dated August 21, 1991,the gears will be available soon and will be registered in WRPC. Wehave found the mode E gear to be the most requested gear
SonyXESC1
PART NUMBER/DESCRIPTION CORRECTIONS: IC-501, IC-502 The part numbers and descriptions shown in the service manualfor IC-501 and IC-502 are incorrect.
SonySTRGX5ES
NO POWER Keeps blowing two fuses, F-801 and F-802. Checked B+ and B-line if there was any resistance showing leaky but it was ok. Also check-ed power A board which looked ok. The difficult part about trouble-shooting this unit is that you cannot see the bottom
SonyXESP1
PART NUMBER CORRECTION: IC-405 (CONTROL BOARD) SN74HC165NS The part number in the service manual for IC-405 on thecontrol board is incorrect.
SonyCCDV220
SHORT LITHIUM BATTERY LIFE The owners manual says the lithium battery will last about ayear, but this customer has a unit in which the battery lasts only 6months. -HQ COMMENTS: Replace Q-715 DTA-144EK on the FC-15 board with DTA-144TKpart number 8-729-903-29.
SonyKV27HSR10
WIGGLY PICTURE, REPLACED IC-301 ("A" BOARD) Wiggly picture as if horizontal interlacing scan lines wereslightly off time. Horizontal output sine wave looked clean on oscilos-cope, DC sources had no ripple. When scoping (applying color bar genera-tor with chroma removed), IC-301 pins 3 and 5 luma
SonyKV32XBR51
BAD CONVERGENCE, REPLACE IC1504 ON D BOARD Intermittently changing dynamic convergence. No correction isachieved with adjustments (accessing tech adjustment menu via remotecontrol). Osciloscope displayed fluctuating sine waves on IC-1503 pin 1and IC-1501 pin 1. Making DC measurements found tha
SonyKPR46DX10
INOPERATIVE FRONT PANEL CONTROLS, REPLACED C-1006 ON H BOARD Inoperative front panel controls after about five minutes, ex-cept power ON/OFF, normal remote control operation. Making DC measure-ments on IC-1001 found that pin 30 (VDD) read about 1.2VDC instead of3.2VDC. When C-1006 was disconnected, voltage norma
SonyCFD770
CD WON'T PLAY The CD section would power up but would not play. I foundXRST from IC-804 was low. This was being dragged down by IC-703A. Thisis the second unit seen with this problem.
SonyDTC700
NO AUDIO No audio. Check X-303, X-302 and X-301. Also credit TonyFonseca with this report.
SonySTRAV710
AFTER CHANGING DISPLAY BOARD, UNIT IS DEAD After changing display board, unit will not power up. CNJB2is marked incorrectly. You must reverse the cable (i.e. the colored wiredoes not go to the dot side. Also credit Jeff Renner.
SonyD66
WILL NOT READ DISC Unit will not read disc. Laser not lighting. Flexible cableis broken right below the solder bridge used for shipping. Also creditTony Fonseca with this report.
SonyICF2010
INTERMITTENT NO AM; CPU LOCK-UP Intermittant no AM operation CPU locks up. Found C-121broken right at solder point. Capacitor must be removed to determine ifit is broken. Also, check C-118. Also credit Tony Fonseca.
SonySPP320
HANDSET CUTS OFF Handset suddenly goes dead because of ID TX design. When talkis pushed, handset cannot retrieve channel to line. This usually happenswhen handset is tapped, shaken or flexed.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.