Dicas Reparação




Modelo - Chassis


Pesquisa: Enviar Dica Resolvida
Resultados 81386
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKV27EXR15
PICTURE GETS DARK INTERMITTENTLY, RESOLDERED R-739 Picture gets very dark intermittently. It shows color only.
SonyCCDFX410
UNIT CHATTERS WHEN FULLY LOADED/UNLOADED Using the mode box when unloading STOP and FWD lights wouldkeep repeating.
SonySTRAV1070X
ERRATIC SYMPTOMS Servicer has four units with the following symptoms:1. Remote may not work. 2. On and Off by itself. 3. E is on display.4. No display. 5. Surround and DRLC relays On and Off by themselves. 6.Cannot turn unit off. Procedure from service bulletin No.
SonyKV20EXR20
LOUD MECHANISM HUM, GLUED SHIELD (T-602) Metal shield around T-602 is loose, causing mechanical 60Hzhum or buzz. Have seen this on sevreal other units also.
SonyCDXA55
PART NUMBER CORRECTION: CONNECTOR FLEXIBLE BOARD (REF. 102) This flex cable does not fit in unit. This part # shows upin the system for model CDX-U300. The part number taken from the flexconnector of the CDX-A55 is 1-643-777-11, which substitutes to1-646-391-11.
SonySPPA60
HANDSET TRANSMIT FREQUENCY IS LOW X-501 is defective preventing IC-501 (PLL) from operatingproperly. X-501 is producting a low amplitude which is not sufficient tocorrectly run IC-501 (PLL). This also prevents the TX frequency frombeing adjusted to the correct frequency. Also applies
SonySPP75
HANDSET TRANSMIT FREQUENCY HIGH OR LOW - REPLACE X-651 X-651 is defective preventing the adjustment of the handsettransmit frequency. The TX frequency can be either high or low. I haveseen many of both circumstances. Also applies to serial number 1127339.
SonySPP85
HANDSET TRANSMIT FREQUENCY HIGH OR LOW IC-651 is defective preventing the adjustment of the handsettransmit frequency. The TX frequency can be either high or low. I haveseen many of both circumstances. Also applies to serial number 41387.
SonySPP75
NO BASE TRANSMIT - DEFECTIVE IC-151 LOADING B+ LINE Found base unable to transmit. Checked Q-253 collector andfound 1V. Lifted pin 17 of IC-151 (VCC) and checked Q-253 again and foundvoltage to return to 3V.
SonySPP75
NO HANDSET TRANSMIT - DEFECTIVE IC-651 LOADING B+ LINE Found handset unable to transmit. Checked voltage at pin 4 ofIC-652 and found 1V. Lifted pin 17 of IC-651 (VCC) and checked pin 4 ofIC-652 again and found voltage to return to 3V. Also applies to serialnumber 1404397.
SonyCCDTR200
AVAILABILTY OF CRYSTAL VIBRATOR X-601 I need the above crystal for a customer's CCD-TR200. It doesnot register in WRPC or Kansas City Parts Center. Is this the correctpart number we are using? If this part will not be available for a longperiod of time, could you please send us 2 (two) piece
SonyDTC59ES
UNIT WON'T COMPLETELY REWIND Unit would play and fast forward correctly, but wouldn'tcompletely rewind a DT120 tape. All play tensions were correct. However,with no tape loaded and mechanism in rewind, turning take-up spindle withfingers revealed high stiffness and drag.
SonyKV32XBR35
WRONG ON SCREEN DISPLAY CHARACTERS,IC2301 OR DATA LINE M-E2 The memu pages (on-screen) show wrong character in onecharacter locaton. 1. In audio sub-menu, the fourth line should be SRSAUTO, but it displays SRS AUVO. 2. In ON/OFF TIMER sub-menu, thelast digit (minutes) for second timer is wrong:Correct (should b
SonyCDPC910
MAGAZINE DOES NOT EJECT As the magazine is being ejected, its lower left corner hitsthe lower left corner of the opening in the front panel.
SonyEVS900
EJECT TAPE OR DOES NOT ACCEPT TAPE Unit completes front loading process then ejects the tape.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads