SonyITA4000
CN901 AND CN902 - PART NUMBERS MISSING No part numbers for CN901 and CN902. -HQ COMMENTS: These connectors are not supplied as Repair Parts. Theyare only available as part of Main Board assy p/n A-3015-458-A.
SonyITA3000
NO RECORD OAM AND DEFECTIVE OGM REMOTE - RESOLDER IC801 Would not record OGM and no OGM remote. I checked signalat IC801/pin 69, DA out, after recording OGM announcement. No signalcame out. Signal is coming in at IC801/pin 75, MIC1. IC801 chip had alot of pins cold soldered.
SonyITA3000
DEFECTIVE RAM TEST - REPLACE JOG SHUTTLE SWITCH (REF 29) After Ram test, press play and stop button, no function.Switch at shuttle block was defective.
SonyITA3000
NO BATTERY BACKUP - RESOLDER TP50 AND TP51 Battery voltage is not reaching to the main board. I checkedbattery contacts TP51 and TP50. There was not enough solder on them.
SonyITA3000
DEFECTIVE RINGER SELECT - INSTALL R735 In answering mode or OGM activation, select switch at 3 ringsis defective. It takes 5 rings to activate OGM at 3 ringer select mode.I found that R735 is missing on the board.
SonyITA3000
DEFECTIVE PLAYBACK OF OGM AND ICM - RESOLDER IC805 OGM and ICM are cutoff after a few seconds of playback, but intest mode unit will pass RAM test. During visual inspection of board,found IC805 to be poorly soldered. Should RAM test have detected thisproblem?
SonyITA3000
LOW SPEAKERPHONE VOLUME - RESOLDER C504 AND C522 Very low audo when using speakerphone. When tracing audiosignal to IC501, I found both caps C504 and C522 torn off their traces.Resoldering these caps fixed problem.
SonyITA3000
NO SPEAKERPHONE - C512 SHORTED No audio is heard when using speakerphone. Checked voltageson IC501 and they measured 4.2v. Found leads on C512 to be touchingtogether, grounding out RV501 speaker volume.
SonyITA3000
DEFECTIVE BELL DETECT - REPLACE PH201, P/N 8-719-156-79 No OGM activation, constant high at PH201 pin 3 (output).PH201 coupler is defective.
SonyITA3000
NO OGM ACTIVATION - C208 MISSING Defective bell detect test. I traced the signal comingout PH201/pin 3, wave form has a lot of ripple at IC701 pin 14 input. Ifound out C208 missing at the main board.
SonyITA3000
DEFECTIVE ANSWER ON/OFF INDICATOR - REPLACE D702 No illumination at answer on mode indicator. I checked D702and it is cold soldered at diode side.
SonyITA3000
DEFECTIVE BELL DETECT - BROKEN TRACE AT TP9 No OGM activation. No signal going into IC701 pin 14. Tracedit down to PH201 output pin 3. It's missing between R208 to IC701 pin 14. I found a broken trace TP9 to R208 resistor.
SonyITA3000
DEFECTIVE BELL DETECT - REPLACE Q301, P/N 8-729-927-24 No ring and its connect or seized a line. I checked Q301collector and emitter shorted together.
SonyITA3000
DEFECTIVE KEYPAD - RESOLDER CONNECTOR CN101 Keypad will not register #, 0 or * out to the phone line.Found an open between CN101/pin 29 and CN102. Resoldering CN101 fixesthis problem.
SonyITA2500
VOX DTMF TEST - REPLACE IC504, P/N 8-759-996-43 No telephone line signal detection on DTMF display. There wasa signal coming in IC302/pin 11 to IC504/pin 2(input). There was no signalon IC504/pin 1 (output). IC504 was defective.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.