Dicas Reparação Thomson








Pesquisa: thomson

Resultados 130

Dicas de reparação para: thomson
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Thomson32WF45E Chassi ICC20Desliga após 5Min de funcionamento imagem no OST/WEST com pequena ondelação leed fica a piscar 2 vezes e depois 5 infinitamente não volta a funcionar ligando novamente,só muito mais tarde.Mudar o CL036 de 2;2Mf no circuito de Ost-West
ThomsonChassis TX91GNão Funciona - led frontal pisca em vermelhoSubstituir Memoria 24C04
THOMSON SABATX807VST = 418Não liga. Fonte chiaDL21 = BAV21
THOMSONChassi TX807CSMorto: Led não acende, fusível e transistor shoper não qeimamVer transistores TP022 e TP032
THOMSONICC7 & ICC8Vertical - TDA8178FS em curto, já não se fabricaSubs. por STV9379F, soldar Res 3K9 entre Pinos 2 e 7, soldar Zen. BZX75C2V1 Anodo Pino 7 Catodo Massa
THOMSON55MT16Não tem SomTA02
THOMSONChassis ICC9Perde a Syncro Linha e TramaTH05 - TH04 - TX16
THOMSONChassis ICC9Fica em StandbyTP66 e TP69 na Alimentação
THOMSON14MG10GTela azul com linhas de retornoTransistor TT72/2SC2482 com fuga base/colector
Saba/ThomsonChassi TX805Avaria do Zener DP50Verificar soldaduras do Pino 5 do TSL até ao electrolitico CP17
Thomson 24WK24U ICC17 Set is tripping with flashing from the red standby lightShort the collector of TL71 to earth, if the set comes on you will find the frame chip is blown and ZL11 cp is o/c. If the set still wont come on them the LOPT is suspect
Thomson TX91 PLL will not lock for all frequencies keeps running during program search, on screen display moving / unstableChanged the tuner and the STV8224 also check transistor at location TV02 is ok
Thomson 28WR23EG ICC17 AV1, AV2 are fine but AV3 do not work. Picture may be ok but no soundReplace BA7604N, and check CX64 47pF
Thomson ICC17 Standby led fault codes and meanings list / standby led flashes then pausesCode meanings are as follows: 10 = child lock mode, 11 = timer mode, 14 = there is no response from Iv01, 15 = there is no response from IS40, 20 = bus access prohibited by software, 21 = bus data line held low, 23 = bus clock line held low, 25 = switched 5v supply missing, 26 = crt is not warming in the allotted time, 27 = deflection failure more than three times, 28 = IF01 guard voltage pin 8 exceeded, 34 = no response from the nvm chip IR03, 36 = incorrect address passed to bus handler, 37 = unexpected level on NMI line power fail, 41 = bus data line not recoverable
Thomson 28WS23E ICC17 Set trips off int. Set tries to come on then goes back to standbyDry joints on line o/p transformer




Verifique se o esquema está disponível na área de downloads