Sharp 4BSC Low width with lines across screen and feathered edgesReplace C623 and C602
Sharp4BSC DV6632Hvery faint colour lines on the topC501 VCEAGA1HW107M, C506 VCEAGA1VW107M leaky
Sharp4BSC DV6632Hrepeated failure of LOPTrresolder scan coil connections
Sharp4BSC DV6632Hline pulling, bent verticalsC623 4.7uF 50V next to Q603 regulator
Sharp4BSC DV6632Hframe foldover at the topC505 100uF 40V
Sharp4BSC DV6632Hburst of EHT then shuts downIC500 TDA8170 s/c R645 1R 1W o/c
Sharp4BSC DV5940Hstuck in stbyD600 1N4936 s/c, R645 1R 1W o/c on LOPTx pin 3
Sharp4BSC DV5940Hdead, LOPTr s/cQ600 2SD1546 s/c, SMD Q606 2SC2412 leaky, resolder scan coil plug
Sharp4BSC 66AS05Hstuck in stby, when brought out LED goes green, quick burst of EHT, then shuts down with LED redSMD Q606 2SC2412 leaky
Sharp4BSC 66AS05HNo line aft repairing dry joints scan coil & LOPTr s/c LEDs sw between Red/Greenleaky s.m. transistor Q606 [2SC2412] in the line drive circuit.
Sharp4BSC 66AS05HNo E-W corr aft replacing TDA8170 FOP chip, R645 & C506 for tripping offQ603 2SD1913S collector base leakage, and C603 4.7uF high ESR
Sharp4BSC 66AS05Hexcessive width with E-W errorL601 shorted turns (RCILP0104CEZZ)
Sharp4BSC 66AS05HDead with tickingLOPTr s/c due to dry joints scan coil plug
Sharp4BSC 66AS05HDead - no line driveIC800 MC44002 jungle chip faulty
Sharp4BSC 66AS05HDead - LOPTr 2SD1546 failedReplacement only lasted days - IC800 MC44002P line drive pin 12 only 1v instead of 3v - chip faulty. Also check state of Q601 2SC2271 dr tr & Q606 pre driver tr



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.