Sharp5BSA 51AT15HHT high at 114v (105v) & EHT varying (can blow BU508DFI (don't fit BU508DF)ZD717 & 718, Q708 (7v supply) faulty
Sharp5BSA 51AT15HGreen LED flashes and dim - no sound/picHT = 113v (should be 105v); Q708 (BC338-40) and D715 (5v1 zener).
Sharp5BSA 51AT15HField foldover & no R/C or local controlQ509[BC635] and Q510[BC338]
Sharp5BSA 51AT15Hfield cramp, no OSD, no vol adjustQ510 BC338
Sharp5BSA 51AT15HField collapse/ R & G lines at top of picBC636 in FOP stage causes field coll & D504 1N4148 causes lines
Sharp5BSA 51AT15Hdead, no LED, HT is Okno 5V supply to jungle IC, Q708 BC338 u/s (RHTX0102BMZZ)
SHARP5BSA 51AT15HDEAD WITH GREEN LEDCHECK Q704 BC338
Sharp5BSA 51AT15HDead st/by onlyNo line drive from MC44007 ic; 5v supply ok in st/by but dropped when sw on - BC338-40 tr cooked up
Sharp5BSA 51AT15HDead BU508DF1 LOPTr s/cReplaced with BU2508DF - given as equiv but DOES NOT work! Use correct Tr & replace C713 1000µ hi esr
Sharp5BSA 51AT15HDead - no start upC713 1000µ 25v hi esr & Q601 BU508DF1 LOP tr s/c
Sharp5BSA 51AT15HDead - no LEDcaps in psu sec plus BU508DF1 & 2SC335-19 dr tr - NOTE MUST use correct replacements or will not work properly IE brushing if dr tr incorrect
Sharp5BSA 51AT15HDead - LOPTr BU508DF1 blownWhen Tr replaced , overheats due to leaky line dr Tr Q602 BC635 - fitted BC639 in lieu (checks ok out of cct)
Sharp5BSA 51AT15HdeadLOPTr reads s/c in situ, check R622 - one of its ends shorting to earth print
Sharp5BSA 51AT15HdeadQ601 BU508DFI s/c (use correct type)
Sharp5BSA 51AT15HDeadC716 100µ hi esr



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.