SANYOCB1443COLOURS WRONG ORDERREPLACE IC270 IC**TDA4662
SanyoCAQO3002W A3A14No sound - ok thro' SCARTIC101 LA7680
SanyoC28WN3Shuts down aft 20 mins with LED flashing 3 times. Will restert if sw of/on again but for progressively less timepress the MEMORY button on the front panel whilst powering the set up, it over-rides the protection circuit. R810 0R33 in psu pri was o/c but main cause was C659 220µ (sometimes 330µ) 250v in B1 supply o/c
SanyoC28WN1St/by only - st/by psu running - main psu u/sChopper Q634 2SC4429, Q633 2SC3807, R902 3R9 10w
SanyoC28WN1St/by onlyR645 120k O/C.
SanyoC28WN1No Txt after psu blow upX2901 27Mhz Xtal
SanyoC28WN1No sound aft psu bow upTA8200H audio amp chip
SanyoC28ER55NBNo tuning above Chan 35 or autostoreTuner - repaired at MCES (NLA)
SanyoC28E55NB EB4-A28Sound dist - comes thro' in dist bursts (normal & surround sound modes)IC653 5v reg supply to nicam ic
SanyoC25G65BNATrips int when coldC 655 100uf @ 10V, C 651 470uf @ 16V
SanyoC25EG95 PatterningC211 0µ01 had not been fitted
SanyoC25EG65NB 25DN1St/by only - LED goes out when sw onR620/621 120k hi res or o/c
SanyoC25EG65NBNo HT adjR644 68k
SanyoC25EG25ND EB2ALoud hum when heated & low gaindry joint on a black insulated wire link that runs from the secondary side of the chopper transformer to one of the regulator chips in the centre of the PCB; check tuner earths for low gain
SanyoC21EF95BComes on briefly then reverts to st/byLine dr stops aft 2 secs HT = 125v; R372 390k o/c in prot cct



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.