Sanyo 21BN1Dead, l.e.d. litR620 o/c. R621 and R620 replaced both 120K
Sanyo VHR-796EDeadPR512 in the PSU was o/c
Sanyo C25EG95B EC3-A25 Dead set no start upReplace R321 120K
Sanyo CE32WP2 WB2-A32 Dead set, standby L.E.D litCheck capacitor C634 2n2, 2KV in power supply for o/c or s/c
Sanyo AVM1902 G4S-19020 Intermittent horizontal deflectionResoldered the pins of horizontal deflection transformer
Sanyo VHR287ECuts out on record and clock blinks out other wise OKReplace PR512 JS130 Light brown 1000 on side near front of PSU next to Q5103
Sanyo VHR766Completely dead, no displayReg IC511 faulty L5431. Replaced solved all problems
Sanyo CEP2190MNo soundIC901 TDA4935 blown due to excessive supply voltage, capacitors C619, C623, C810, C600, C601, C859 defective. Also verify R822
Sanyo CEP3011V-30 A1-B14 After switching on, no longer able to switch-off with remote control, standby light comes on with sound muted. Original remote control: RM-700Opto-coupler PC113 faulty
Sanyo Spectra 2000Picture had only wide screen effectFound set on the street ! beautiful little 14" tv, still looks like new, replaced 33uF, 160v cap in power circuit as it was bleeding its guts onto the pcb, has worked perfectly ever since !
Sanyo VHR776EDeadCheck and replace PR512 which is located towards the front right hand side
SANYOCTP-3771Fonte AltaR552 alterado
SANYOCTP-3792Faixa escura do lado direitoDIODO ZENER-D351-15V
Sanyo ED1Unable to change chans via front or r/cAdjust G2 volts - micro tied up due to low emiss crt
SanyoED1 CBP2872No colourPVPU2204 chip



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.