SintomaCausaSoluçãoPor:
Jvc C14E1EKDead, in standby, HT present at relay RLX401, no 12 volts at C419R425 5.6ohm o/c, ZD402 12 volt zener s/c and C426 2200uF, 25volt faulty
Jvc C14E1EKTuning drift,worse at high channel no'sDry joints inside tuner unit, connections between edge of pcb and lugs
JVCC14E1EK OnwaSet comes on to standby - relay clicks.R323 ( 6k8 5watt ) fusible resistor o/c ( maybe Int ) between p42 of IC301 & HT rail.
JVCC14E1EK OnwaNo goR323 ( 6k8 5watt ) fusible resistor o/c between p42 of IC301 & HT rail.
JVCC14E1EK OnwaInt snowy pic at sw on with no OSD or R/C functsOK once TMS73C47 micro reset (s/c pin 32 to chassis briefly). Caused by crack in print at front edge of pcb on track to pin 2 micro - hard to see due to covered in black ink
JVCC14E1EK OnwaDead - no st/byQ902 2SB774 base emitter s.c. (used BC558).
JVCC14E1EK OnwaDead - HT highC909/911 47µ cured HT problem but still dead; No supply pin 42 AN5601K dec/tb chip IC301. R323 6k8 5w fusible o/c
JVCC14E1EK OnwaDeadAfter replacement of usual caps the mains smoother C907 4700pF 500v in psu pri was found to be leaky
JVCC14E1EK -OnwaSt/by only - can be intlop stage 12v low at 11.5v - R434 0R68 hi res at 1R2
JVCC14E1EKTuning driftC116 sm cap - also check other sm electrolytics whilst tuner out
JVCC14E1EKStuck in StBy , relay clicks but no go . Or very rarely comes on and then goes to StBy after 3-4 mins .R323 6K8 5w fusible OC.
JVCC14E1EKSt/by onlyC406 220µ 25v
JVCC14E1EKNo TxtSAA5243P/E on Txt pcb faulty
JVCC14E1EKLine TearingC632
JVCC14E1EKInt destruction of fop chip (IC401 LA7830)Replace VR901 (2K) +B preset.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.