Jvc AV25S1EKField collapseResolder TDA3654 as joints appear good but on application of soldering iron show to be dry
Jvc HRJ205Dead, no negative voltages on psu connectorCheck R32 100 ohms in psu for o/c
Jvc HR-S4700EKIntermittently crunches tapes on ejectI had to use a clear service cassette to see what was occuring during the eject sequence and found that during the unthread, the take up reel was rotating anti-clockwise and was not being braked, the felt pad on the take-up sub brake had fallen off the arm, a new brake cured the problem
Jvc HRJ235EKRubbing noise at start of full tape with horizontal picture judderExcessive take up tension! Replace take up clutch item 25, Pt no PQ46323A-1
Jvc C-V14EKS/B/W Onwa No RedI was hoping the nvm had become corrupt and turned the red drive down but it was fine To enter service mode press and hold vol up and vol down on the front panel and switch set on. Thankfully ZD405 8V2 had expired almost s/c and removed the red
JVCDead - st/by onlyR323 6k8 5w fusible res o/c connects pin 42 of IC301 to HT rail
JVCSX2, TS2Crackle on NICAMReplace SAWF with pt no CE42606-T01
JVCS2180MField collapseCheck UPC1488H FOP chip & supply to it - if missing, check cp IC 10NR for o/c
JVCOnwaSt/by onlyNo line feed - 6k8 2w resistor in middle of pcb discoloured & o/c
JVCOnwaSound int & paired lines at bottomR434 0R68 ½w hi res
JVCMX2Flyback lines at bottom of screenIncrease value of C442 from 150pf to 470pf
JVCMX2Field int collapsesD441 RD3.0ES(B2) goes leaky when warm - to pin 13 TA8859P IC461
JVCJXBlank raster when A1 advanced - sound okTDA4580 RGB vid controller chip
JVCJAField scan missing from topIC401 (fop chip) pin 4 = 14.5v, pin 8 = 42v but was low because FR553 5R6 ½w o/c. eplaced along with TDA8350Q fop chip
JVCCY21EKInt goes to st/byDry joint X401 resonator by IC401 caused int line drive



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.