Dicas Reparação




Modelo - Chassis 2100


Pesquisa: 2100 Enviar Dica Resolvida
Resultados 95
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Proline2100
TEXT "WOBBLY"XR101 RESONATOR
NakioN2100TX
Dead apart from tickingHT low - C5 100mfd 400v mains cap o/c
BushITV2100
Sound int goes with crackle aft 1/2 hrAlthough freezing O/P IC TDA7263 temporary cure - 18Mhz Xtal was faulty
AmstradSTV2100N
Red tint variesBlack conductive gunge near dec chip - scrape away all gunge
AmstradSTV2100N
Cuts out to snow. No Nicam LEDs, goes to st/by when heatedTest point between NICAM pcb & tuner screening can shorting together
SONYKV-2100E
quando liga aparece a imagem mas por breve segundos ( 1 ou 2 ) depois fica com a tela totalmente baça e não se vê imagem.D504 com fuga1N4148
PhilipsLC2100
TELA ESCURA "PRETA" (VEJA TAMBEM BRIL4). Transistor 7360 aberto. * 17Jan97 JPBA *. Verificar TDA4680, a lampada acende normal. * 31Mar97 JPBA. Verificar tensoes no 7325/7360/7385/7430, caso encontrado alguma tensäo baixa provabilidade de um deles com defeito. * 09Out97 JPBA *.
PhilipsLC2100
TELA CIANO (SEM VERMELHO) = VERM1 CIRCUITO INTEGRADO 7366 (TDA4660). * ABR 95 ANC *.
PhilipsLC2100
SEM SINCRONISMO VERTICAL (VERT5). Verificar integrado 7412 (TDA2579C), so funciona adequadamente com esta máscara. * 16Set97 JPBA *.
PhilipsLC2100
NAO FUNCIONA (FICA COMO DESLIGADO). Verificar resistor 3163 (1Û) aberto. * 31Mar97 JPBA *.
PhilipsLC2100
LED(S) PISCANDO. (REPETITIVAMENTE) Verificar resistor 3163 (1Û) aberto. * 31Mar97 JPBA *.
SpectroAmplif SQA 2100
Canal esq c/ volume baixoC123 (47 µF 16 V)
SonyCDX2100
LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163).
SonySPP2100
HANDSET CUTS IN AND OUT DURING C0NVERSATION Handset cuts in and out during conversation. Battery terminalsin handset were not making secure contact with the battery. They wereeither bent out of shape (due to pressure exerted by battery when pushedin), or desoldered. If ref 16 (battery terminal) is
SonySPP2100
LOW BATTERY AFTER CHARGING. Customer states they have low battery after charging for longtime.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads