Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Toshiba | 2100TB | Field - lack of height | C317 2µ2 | ||
Toshiba | 2100TB | Field - excess height/poor lin | C303 2µ2 50v in field drive near pin 32 TA8659 | ||
Toshiba | 2100TB | Excess height at sw on with poor lin | C303 2µ2 pin 32 IC501 | ||
Toshiba | 2100T | int. band of lines at bottom | resolder frame IC | ||
Toshiba | 2100RBT | STBY LIGHT FLASHES BUT SET WON'T GO | C820 120uF 400v | ||
Toshiba | 2100RBT | HUM ON CHROMA - VARIES WITH COL CONTROL | C515 ( 22mfd 50v ) | ||
Toshiba | 2100RBT | DEAD SET , Q802 FAILS AT SW.ON | R810 HIGH OR OPEN 330k | ||
Toshiba | 2100RB 2101T 210 | INT PARTIAL FIELD CVOLLAPSE | IC408 12v REG OP. LOW PT No. Toshiba 23318218 | ||
Toshiba | 2100RB | Field lin | C303 3µ3 near jungle chip | ||
Toshiba | 2100RB | Field collapse | AN5515 FOP chip, 100µ 35v & 2µ2 35v close to chip, R327 6R8 1w o/c | ||
Toshiba | 2100DB5 | NO SYNC | REPLACE TEXT ICs ( CHECK ON WHITE LABEL FOR EXACT MODEL TYPE ) | ||
Toshiba | 1400TBT, 2100TB etc | Field cramp at bottom - stretched at top | C303 2µ2 | ||
Sony | KVM2100D | EAST-WEST Won't adjust properly. Excessive width. | Change capacitor 47nF/400v parallel to E-W diode | ||
Proline | NV2100 | NO SOUND OR PICTURE RASTER OK | DRY JOINT ON END PIN ON AV BOARD (LEFT END) | ||
Proline | NV2100 | no pic, no sound. HT Ok but no 18V supply to line driver | resolder end pin of AV PCB connection to main PCB (left end of PCB when looking from rear of set, the 18V is fed thru this PCB) |