Grundig1000 series
No power upTR540 BC847 in micro reset circuitry.
Finlux1000/3000
DeadBY299 17v rect or Du16 138v HT rect
Finlux1000 srs EARLY
INT COLOUR , SEEMS LIKE DRY JOINTSCt12 REF OSC TRIMMER NOISY . LINK PINS 25 , 26 AND 1 , 5 TO SETUP
Finlux1000 early
No pic - crt htrs alightCb 2µ2 35v o/c (near col dec chip)
Finlux1000 -early
Int col with TDA3652A chipref osc trimmer Ct12 6-30pf noisy. To set up link pins 24/25 & 1/5 of ic & adj Ct12 for stationary col
Finlux1000
This set would start off all right. But after abouCh11 ( 47uF , 63V )
Finlux1000
Standby - going into standby intermittently.DA1 ( IN4007 ) in vision IF.
Finlux1000
Raster - white.DA1 ( IN4007 ) on vision IF.
Finlux1000
No sound or picture - EHT ok.Ri20 ( 100R ) o/c.
Finlux1000
NO SOUND OR PICTURENO LINE DRIVE Ta2 BC547 OC
Finlux1000
No sound or pic - line drive missingTa2 BC547
Finlux1000
No sound & sw to st/by aft 10 mins (no sync)Check pin 13 ICh1 TDA2578A TB chip should be high - was only 0.5v (transmit ident) - chip faulty
Finlux1000
No picture or sound - EHT ok.Ri20 ( 100R ) o/c.
Finlux1000
Int various inc red/green/off/false line lock/line tearing12v supply low due to Ta8 BD241 - also check Da1
Finlux1000
int st/bylopt has hole in it


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.