Dicas Reparação THOMSON




Modelo - Chassis


Pesquisa: THOMSON Enviar Dica Resolvida
Resultados 130
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
ThomsonICC17 24WK24U
Tripping with red LED in sympathyTo disable trip s/c TL17 e-c; blank raster with fb lines now present; Field fback supply missing due to ZL11 MP25 o/c
ThomsonICC17 21DK24U
St/by LED flashes - comes on using R/C but excess brill with fback lines196v HT to IB01 TDA6107Q RGB o/p chip missing on crt base - RB06 220R o/c
ThomsonICC17
No sound or vision - low hummingTS81 BC847B sm leaky c-e
ThomsonICC17
LED gives 3 orange flashes LOPTx
ThomsonICC17
Excess width & E-W faultyTL41 BD241C dry jointed, DL22 BYW76 s/c
ThomsonICC17
EW faultyDL22 BYW76 leaky, TL41 BD241C driver u/s, TL42 BC546B u/s, s/c across DL42 caused by IV01 64 pin sm TDA8855H jungle chip
ThomsonICC17
Destroys LOPTrs & E/W unstableCL22 22nf 1kv O/C across E/W diode
ThomsonICC17
Dead - no main psu start upCrack in print front control panel - no supply for st/by LED & R/C rx
ThomsonICC11 72MK89D
Luminance lostCheck with scope pin 14 Pl/skt BV001. If vid signal missing or crushed check T130, 132 & 134 in IF module. If good signal here check vid signal at TV001 under screen in vid module. If no sig here TV681 &/or TV682 can be responsible. If sig at TV001 ok, TV002/3 are faulty
ThomsonICC11 72MK89D
Excess brightness with fb linesRL128 1M8 in A1 pot divider on dynamic focus module
Thomson32WT45U
Flyback lines then pulsing pic when A1 reducedLOPTx 10675710
Thomson32WS83KP
Dead & trippingHT ok at 95v when lop dis'd - IB01 TEA5101B RGB o/p chip on crt base
Thomson28WF45E
No B No B-Y signal. IV100 TDA9178 U/S.
Thomson21CB26VN
Dead - psu works on dummy loadRP531 100R sm o/c (had prev had FOP chip IF01 & chopper FET TP20 changed)
Thomson20CB25UT
TV cuts out aft 10 secs - video sect deadR002 1R o/c on video


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.