DaewooCP775
Dead with psu running No or low line drive at base Q402 line dr - check Trs Q405 2SA854 & Q406 2SC945 for leak
DaewooCP775
Dead - lop tr Q401 2SD1880 s/cC416 blue disc cap 680pf 2kv s/c. D503 1N4148 s/c; RC527 10R chip res; R503 10k; R409 4k7 were cause of problem
DaewooCP760
pic displaced to leftcrack in pin 10 loptx - no fback pulse to line gen AFC loop
DaewooCP420 GB14F7T1
Int reverts to st/byRLY2 relay was operating when fault occurred - IC I807 (TOP210-PF1) the standby switch mode IC in the power supply
DaewooCP380
Blank raster, no sound, osg or r/c when first switched on (OK after re-switched on)Earth speakers/grill to crt rimband
DaewooCP365
Sound - int crackleInvisible dry joint C808 270pF 1Kv - pin 3 pri of chopper Tx
DaewooCP365
Int signalsDry joints sec of chopper tfmr
DaewooCP365
Int loss of signals - OSD okDry joints chopper tfmr
DaewooCP340
Int sw offTOP210PFI, I807
DaewooCP330/CP365
Txt absent/garbledXT01 27Mhz Xtal
DaewooCP330/CP365
No pic or line driveCheck drive pin 37 I701 TDA8362B, if none check 8.2v pin 36, if present replace chip, if absent check R401/2, D401
DaewooCP330/CP365
Magenta cast after I501 replacementI501 TDA4661 chroma delay line chip could be faulty
DaewooCP330
Jumps chans and sound varies24C08P Eprom memory chip IV02 - use Daewoo type
DaewooCP310
St/by only - relay clicks at sw onReplace HT pot VR801 4k7, D807 BYV95C, Q801 2SD1555 & I801 chopper chip TDA4601 & check for dry joints
DaewooCP240 GB20F8T2
To set up & service mode…Put set in standby then press blue yellow green red & standby to get into svc, to adjust use 4 & 7, vert centre 5 & 8 size 6 & 9 slope yellow, blue horiz centre 123 & above to ajust RGB


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.